SyncValsverifier → artifact → classifier → verdict
SyncVals · Trajectory

bcd-tens-rollover

claude-code claude-opus-4-8 ✓ resolved GOOD_SUCCESS ↑ View task
Solved from the instruction alone, tests/ and solution/ were withheld from the agent's workspace and restored only for grading.
Reward = tests/test.sh exit code (0 → resolved); the classification below is post-hoc and cannot change it.
Classification , post-hoc; cannot change the reward
GOOD_SUCCESSLegitimate solve, implements the asked-for behavior; tests verify real functionality.
SubtypeLegitimate Solution
EvidenceAgent trajectory shows only a Write to /app/dut.sv implementing TopModule with hidden units, BCD tens wrap, and delayed roll_pending/roll_o logic. Verifier output: "TEST reference_equivalence: PASS (all 8681 samples matched reference)" and "TEST dut_forbidden: PASS (no forbidden constructs)". Tests compare tens_o and roll_o against RefModule over reset, idle, continuous increment, random streams, and 99->00 wrap scenarios.
Root causeThe agent implemented the behavior specified in instruction.md: synchronous reset, two-digit BCD counting with only tens_o exposed, and a registered one-cycle delayed roll_o pulse after units rollover. The tests validate the requested behavior rather than superficial implementation details, and there is no evidence of test or solution access.
RecommendationN/A - task is fine
Trajectory
Tool-by-tool agent trajectory
1 tool calls · 1 tool types · 3 steps
Write /app/dut.sv defining TopModule with ports clk, rst, inc_i, tens_o[3:0], and roll_o; rst is synchronous active high. Track a two-digit BCD counter from 00 through 99, but expose only the tens digit. On a rising clock with rst high, clear the hidden units digit, tens_o, and roll_o to 0. On any other rising edge with inc_i high, increment the counter once; with inc_i low, hold the count. When the hidden units digit increments from 9 to 0, increment the tens digit, wrapping 9 to 0 for the 99 to 00 transition. tens_o must always be a valid BCD value 0 through 9. roll_o is registered and pulses for exactly one clock one full cycle after the new tens_o value first appears because of a units 9 to 0 rollover. It must not pulse on the same edge that changes tens_o, and it must clear to 0 on the following edge unless another delayed rollover pulse is due. Helper modules are allowed in the same file. Do not use simulator/file-I/O system tasks, include/define/undef/conditional directives, DPI, force/release, or hidden grader identifiers.
write · /app/dut.sv
module TopModule (
    input  wire       clk,
    input  wire       rst,
    input  wire       inc_i,
    output reg  [3:0] tens_o,
    output reg        roll_o
);

    // Hidden units digit of the two-digit BCD counter.
    reg [3:0] units;

    // Registered "rollover happened" flag, delayed one cycle so that
    // roll_o pulses one full clock after the new tens_o first appears.
    reg roll_pending;

    // Combinational detection of a units 9 -> 0 rollover on this edge.
    wire rollover_now = inc_i && (units == 4'd9);

    always @(posedge clk) begin
        if (rst) begin
            units        <= 4'd0;
            tens_o       <= 4'd0;
            roll_o       <= 1'b0;
            roll_pending <= 1'b0;
        end else begin
            // Second pipeline stage: emit the delayed rollover pulse.
            roll_o <= roll_pending;

            // First pipeline stage plus the actual counting.
            if (inc_i) begin
                roll_pending <= rollover_now;
                if (units == 4'd9) begin
                    units  <= 4'd0;
                    tens_o <= (tens_o == 4'd9) ? 4'd0 : (tens_o + 4'd1);
                end else begin
                    units <= units + 4'd1;
                end
            end else begin
                roll_pending <= 1'b0;
            end
        end
    end

endmodule
Created `/app/dut.sv`. **Design summary:** - **Counter** , a hidden `units` register (0–9) plus the exposed `tens_o` (0–9). When `inc_i` is high, `units` increments; on the 9→0 wrap it resets and `tens_o` advances, wrapping 9→0 for the 99→00 transition. When `inc_i` is low, everything holds. - **Two-stage rollover pipeline** , `rollover_now` combinationally detects a units 9→0 event on the current edge. That gets captured into `roll_pending` on the *same* edge that changes `tens_o` (so `roll_o` stays 0 there), and `roll_o <= roll_pending` shifts it out on the *next* edge. Result: `roll_o` pulses for exactly one clock, one full cycle after the new `tens_o` appears. - **Clearing** , `roll_o <= roll_pending` runs every non-reset edge, so the pulse self-clears the following edge unless a new rollover reloaded `roll_pending`. The pulse fires even if `inc_i` drops low in the intervening cycle, since it's driven purely by the registered flag. - **Sync reset** , active-high `rst` clears `units`, `tens_o`, `roll_o`, and the pending flag on the rising edge. Only synthesizable RTL is used , no system tasks, macros, DPI, or `force`/`release`.
Final diff , what the agent changed

No file changes, the agent left the workspace untouched.

Verifier output , the proof behind the reward
tests/test.sh
TEST dut_present: PASS (/app/dut.sv exists)
TEST dut_forbidden: PASS (no forbidden constructs)
TEST harness_prepare: PASS (harness names nonce-renamed)
TEST dut_compiles: PASS (compiled with held-back reference/testbench)
TEST simulation_completed: PASS (Mismatches: 0 in 8681 samples)
TEST reference_equivalence: PASS (all 8681 samples matched reference)

Reproduce this trial: git checkout 2f94510 && PYTHONPATH=src python3 scripts/build_site.py , then open trial/trial_36eb7c5712964bd1. Re-running the agent live requires EVAL_PLATFORM_ENABLE_OAUTH_SMOKE=1 and is non-deterministic.

Trial trial_36eb7c5712964bd1 · verifier authoritative; classifier explanatory.